V.4 Neurosurgery Planning Hanging Protocol Example

Goal: A Hanging Protocol for MR & CT of Head, for a neurosurgery plan. 1Kx1K screen on left shows orthogonal MPR slices through the acquisition volume, and in one presentation group has a 3D interactive volume rendering in the lower right quadrant. In all display sets the 1Kx1K screen is split into 4 512x512 quadrants. The 2560x2048 screen has a 4 row by 3 column tiled display area. There are 4 temporal presentation groups: CT new , MR, combined CT new and MR, combined CT new and CT old .

Display Environment Spatial Position attribute values for image boxes are represented in terms of ratios in pixel space [(0/3072, 512/2560), (512/3072,0/2560)] rather than (0.0,0.0), (1.0,1.0) space, for ease of understanding the example.

[pic]

V.4.1 Hanging Protocol Definition Module

Hanging Protocol Name: “NeurosurgeryPlan”

Hanging Protocol Description: “Neurosurgery planning, requiring MR and CT of head”

Hanging Protocol Level: “SITE”

Hanging Protocol Creator: “Smith^Joseph”

Hanging Protocol Creation DateTime: “20020101104200”

Hanging Protocol Definition Sequence:

Number of Priors Referenced: 1

Image Sets Sequence:

Hanging Protocol User Identification Code Sequence: zero length

Hanging Protocol User Group Name: “ABC Hospital”

V.4.2 Hanging Protocol Environment Module

Number of Screens: 2

Nominal Screen Definition Sequence:

V.4.3 Hanging Protocol Display Module

Display Sets Sequence:

[Group #1 is CT only display (current CT)]

[pic]

[Group #2 is MR only display]

[pic]

[Group #3 is combined MR & CT]

[pic]

[Group #4 is combined CT new & CT old]

[pic]

Partial Data Display Handling: “MAINTAIN_LAYOUT”

[Link up (synchronize) the MR and CT tiled scroll panes in Display Sets 15 and 16, and the CT new and CT old tiled scroll panes in Display Sets 21 and 22]

Synchronized Scrolling Sequence: